VPG {vpg_name} exceeds configured RPO of {n} by more than {m}%.
Description
The IOs are not being replicated fast enough and this is causing the current RPO for the VPG to be at least 25% more than the target RPO specified in the VPG SLA settings.
This alert is triggered when the actual RPO, the time between writing checkpoints to the journal, is more than 25% of the target RPO specified for the VPG.
Note: When the RPO is being met, after this error, the following alert is issued: VPG {vpg_name} meeting configured RPO of {n}.
Possible Cause
Possible Resolution
IO burst.
After the IO burst the RPO should return to under the target RPO setting.
VRA is a bottleneck.
Increase the reserved RAM for the protection and recovery site VRAs.
The network is slow.
Check the network rate to see if this is the problem.
The recovery storage is slow.
Check the IO rate for the recovery storage to see if this is the problem.